Common methodological shortcomings were un-blinded assessment, uncertainty about other measurement errors and absence of gold standards. Sample sizes in the included studies ranged from 24 to 683. The mean age of all participants was 45 years, with mean age in the individual studies ranging from 34 to 82 years. Age, diagnosis and number of participants in individual studies are presented in Table 1. The exercise tests
listed above were all assessed by one study each, except for the conventional Åstrand test (three studies), the 5-minute walk test (three studies), and a submaximal bicycle ergometer test following this website a protocol other than the Åstrand test (three studies). No data regarding maximal exercise tests in the population of interest were identified. The data extracted from studies of submaximal tests are presented in Table 1. The psychometric properties of each submaximal test are summarised descriptively, below. Four studies evaluated the reliability, concurrent validity and dropout rates of the Åstrand test, the modified
Åstrand test or the Lean body mass-based Åstrand test. Based on 19 participants, Hodselmans et al reported the test-retest reliability of the Lean body mass-based Åstrand test as an ICC of 0.91 (95% CI 0.76 to 0.97), which changed to 0.96 (95% CI 0.91 to 0.99) when one outlier was excluded.30 The limits of agreement for the Lean body mass-based Åstrand test were 32.0 and 32.8% including the outlier, and 13.8 and 16.9% excluding the outlier. Assessing the conventional Åstrand test in 31 participants, Keller et al showed a test-retest reliability ICC of 0.96 and a critical difference of BGB324 datasheet 21%.32 Based on these studies, test-retest reliability seems to be excellent.
Smeets and van Soest evaluated the concurrent validity of the Åstrand test with a modified Åstrand test in 31 participants with musculoskeletal pain disorder.35 They reported an intraclass coefficient of 0.79 between the two tests. The limits of agreement for VO2max were 15.9% from the mean difference, which equated to 8.5 ml/kg of lean body mass per Parvulin minute in VO2max. Viitanen evaluated the concurrent validity of the Åstrand test with a modified Åstrand test and a 2-km walk test in 69 participants.39 The ICC was 0.20 (95% CI –0.29 to 0.50) at entry of the study and 0.47 (95% CI 0.15 to 0.67) after 3 months. In addition, Spearman’s rank correlation between these two tests was low: r = 0.37 (p < 0.01) at entry and r = 0.34 (p < 0.01) after 3 months. These tests showed low and non-significant correlations with the visual analog scale for pain, with r-values ranging from 0.11 to –0.19 for the Åstrand test and 0.09 to –0.22 for the 2-km walk test. Smeets and van Soest described a slight underestimation of VO2max with the modified Åstrand test,35 with VO2max outcomes an average of 9.96% higher when the conventional Åstrand test was used (95% CI 6.4 to 13.5%) in the pain group.